Comparison of Gait After Syme and Transtibial Amputation in Children

第一作者:Kelly A. Jeans

2014-12-08 点击量:469   我要说

Kelly A. Jeans,Lori A. Karol,Donald Cummings,Kunal Singhal


Background: Preservation of maximal limb length during amputation is often recommended to maximize the efficiency and symmetry of gait. The goals of this study were to determine (1) whether there are gait differences between children with a Syme (or Boyd) amputation and those with a transtibial-level amputation, and (2) whether the type of prosthetic foot affects gait and PODCI (Pediatric Outcomes Data Collection Instrument) outcomes.


Methods: Sixty-four patients (age range, 4.7 to 19.2 years) with unilateral below-the-knee prosthesis use (forty-one in the Syme group and twenty-three in the transtibial group) underwent gait analysis and review of data for the involved limb. The twelve prosthetic foot types were categorized as designed for a high, medium, or low activity level (e.g., Flex foot, dynamic response foot, or SACH). Statistical analyses were conducted.


Results: Kinematic differences of <4° in total prosthetic ankle motion and 8° in external hip rotation were seen between the Syme and transtibial groups. Ankle power was greater in the transtibial group, whereas the Syme group had greater coronal-plane hip power (p < 0.05). Prosthetic ankle motion was significantly greater in the high compared with the medium and low-performance feet. However, the PODCI happiness score was higher in patients with low compared with medium-performance feet (p < 0.05).


Conclusions: Small differences in prosthetic ankle motion and power were found between children with Syme and transtibial amputations. Ankle motion was greater in patients using high-performance feet (9% of the total cohort) compared with medium-performance (59%) and low-performance (31%) feet. Despite the increased ankle motion achieved with high-performance dynamic feet, this advantage was not reflected in peak power of the prosthetic ankle or the PODCI sports/physical functioning subscale.

分享到: