Biocompatibility, biodegradation, and neovascularization of human single-unit platelet-rich fibrin glue: an in vivo analysis

第一作者:Wu Xiuwen

2014-03-11 点击量:559   我要说

Wu Xiuwen, Ren Jianan, Yao Genhong, Zhou Bo, Wang Gefei

Gu Guosheng, Luan Jianfeng and Li Jieshou


Background The clinical applications of fibrin glue span over several surgical modalities. The aim of this study was to evaluate the biocompatibility and biodegradation of different formulations of platelet-rich fibrin glue in vivo and examine its effects on the neovascularization of wound sites.


Methods Human-derived single-unit fibrin glue was prepared. Incisions were made on the backs of rats, and these were coated with homemade glues containing different concentrations of aminomethylbenzoic acid (Groups A–F) or commercial adhesives (Group G). A sham control group was included (Group H). The wounds were examined by histological analysis and immunohistochemistry at several time points.


Results Successful wound closure was achieved in all groups by day 12. Acute inflammation occurred during the first six days, but gradually disappeared. The longest sealant duration was achieved using the lowest concentration of anti-fibrinolytic agent in a 1:10 volume ratio with cryoprecipitate. Expression levels of the platelet endothelial cell adhesion molecule-1 were significantly higher in Groups A and C compared to the control groups (Groups G and H) on day 3 (P <0.05).


Conclusions Single-unit platelet-rich fibrin glue has excellent biocompatibility and is associated with the upregulation of neovascularization. The addition of aminomethylbenzoic acid could prevent the degradation of fibrin glue.



分享到: